1  2  3  4  5  6 

SGI Parkade

Regina, Saskatchewan

Building size: 11,500 m²
Owner: SGI Canada

The SGI Building Parkade consists of three levels of underground parking below the main office tower. The floor slabs are cast-in-place concrete, post-tensioned (P.T.) slabs. The parkade has suffered from P.T. strand breakage due to moisture infiltration. J.C. Kenyon Engineering has provided engineering services to SGI for inspection, monitoring and replacement of P.T. strands since 1995.

 

SaskTel Parkade

Regina, Saskatchewan

Year: Ongoing

JC Kenyon Engineering provides structural engineering services for annual inspections and upgrades to this post-tensioned concrete structure.

 

Hill Centre Parkade

Regina, Saskatchewan

Year: Ongoing

JC Kenyon Engineering provides structural engineering services for the annual assessments and upgrades to this concrete parking structure.


Parkade Repairs - Sturdy Stone Centre

Saskatoon, Saskatchewan

Year: 2014

JC Kenyon is providing structural engineering services as a continuation of the repair work completed at the Sturdy Stone Centre from 1998 to 2012.  This project involves membrane and soffit repair at Sturdy Stone Centre in Saskatoon, Saskatchewan.

McIntosh Parkade

Regina, Saskatchewan

Building size: 12,000m²
Client: Ministry of Government Services
Year: Since 2007

The McIntosh Mall Parkade is a post-tensioned concrete structure. J.C. Kenyon provides engineering services for post-tensioning repairs, traffic deck membrane work and general structural upgrades on an annual basis.

 

       
Home | Employment | Services | Contact